현재 위치
홈상품상세정보

FAQ
How is this membrane different from Gore-Tex® and Cytoplast® membranes?
Micro porous Cytoflex® Tefguard® was designed to improve upon experiences learned from Gore-Tex® and Cytoplast® membranes. Macro porous Gore-Tex® was the gold standard of barrier membranes for use under primary soft tissue coverage. The macro pores were designed for tissue ingrowths to stabilize tissue/barrier interface. However, membrane removal after bone regeneration is traumatic. The featureless Cytoplast® membrane was designed to block off soft tissue and bacteria ingrowths, allowing the barrier to be used in non-primary coverage conditions. The relatively non-porous nature of the barrier limits nutrient permeation across the membrane. Cytoflex® Tefguard's® proprietary micro pores were designed to allow nutrient permeation and at the same time prevent penetration of soft tissue and bacteria across the membrane. The combination of nutrient diffusion and micro porous texture enhances soft tissue attachment while preventing bacteria penetration across the membrane.
What about primary soft tissue coverage of the membrane?
Cytoflex® Tefguard® membranes were designed to serve as a barrier to contain the bone graft material and prevent soft tissue and bacteria in-growth. At the discretion of the practitioners, the barriers have been used in primary coverage and non-primary coverage situation when soft tissue coverage is lacking. The membrane was designed to block off bacteria and thus exposure of the membrane does not result in infection and case failure.
How long can the membrane stay in place?
In general within four to five weeks the membrane will need to be removed. This will allow enough time for the osseous tissue to begin forming and to be able to resist soft tissue from invading the graft site. However, at the discretion of the clinician, primary closure and longer healing times may be considered, if desirable.
How to remove the membranes?
Under primary coverage condition, Cytoflex® Tefguard® membrane may be easily removed by creating a small incision in its proximity. With forceps, firmly grasp a border of the material and remove it from the tissue. Local anesthesia is normally used for this procedure. In non-primary coverage situation, the membrane may be lifted with a periodontal probe and extracted with a forcep. After membrane removal, re-epithelialization will occur within two to three weeks to complete the healing process. Final bone maturation will take place for six to twelve months from the time of implantation. This time frame should be considered in treatment planning cases involving heavy prosthetic loading of regenerated bone.
What is the difference between the Smooth and Textured Cytoflex® Tefguard® barrier membranes? What are the benefits of each as opposed to the other?
Both Cytoflex® Tefguard® membranes have micro-texture. The micro texture allows for better soft tissue attachment over the membrane and a better seal around the bone graft area. The Textured Cytoflex membranes also provide a visible macro-texture similar to the configuration of strawberry fields as opposed to the conventional pot-hole design of other barrier products. This strawberry field texture was designed to further enhance soft tissue attachment and minimize dehiscence over the grafting site.
Can unused portions of the membrane be resterilized?
No, Cytoflex® Tefguard® membranes are designed for a single use only.
What is the shelf life the Cytoflex® Tefguard® membranes?
Each sterile Cytoflex® Tefguard® barrier is double packed and has 6-year of shelf life from the date of manufacture.
Have you ever had a confirmed allergic reaction to micro porous Cytoflex® Tefguard® membranes?
Cytoflex® Tefguard® membranes are made of inert and biocompatible PTFE materials. Since it was cleared in 2002, there have not been any reported allergic reactions caused by Cytoflex® Tefguard® PTFE barrier.
Are there any contraindications?
Cytoflex® Tefguard® membrane is a passive, non-load bearing material and should not be used for load bearing applications. Cytoflex® Tefguard® should not be considered for patients where general oral surgery is not advisable.
What are the potential complications?
Possible complications associated with any oral surgery include infection, flap slough, perforation, abscess formation, bone loss, pain and complications associated with the use of anesthesia. Depending upon the type and severity of the complication, as judged by the clinician, early material removal may be required.
배송안내
- 배송비 : 기본배송료는 3,000원 입니다. (도서,산간,오지 일부지역은 배송비가 추가될 수 있습니다) 40,000원 이상 구매시 무료배송입니다.
- 본 상품의 평균 배송일은 0일입니다.(입금 확인 후) 설치 상품의 경우 다소 늦어질수 있습니다.[배송예정일은 주문시점(주문순서)에 따른 유동성이 발생하므로 평균 배송일과는 차이가 발생할 수 있습니다.]
- 본 상품의 배송 가능일은 0일 입니다. 배송 가능일이란 본 상품을 주문 하신 고객님들께 상품 배송이 가능한 기간을 의미합니다. (단, 연휴 및 공휴일은 기간 계산시 제외하며 현금 주문일 경우 입금일 기준 입니다.)
교환 및 반품안내
- 상품 택(tag)제거 또는 개봉으로 상품 가치 훼손 시에는 상품수령후 7일 이내라도 교환 및 반품이 불가능합니다.
- 저단가 상품, 일부 특가 상품은 고객 변심에 의한 교환, 반품은 고객께서 배송비를 부담하셔야 합니다(제품의 하자,배송오류는 제외)
- 일부 상품은 신모델 출시, 부품가격 변동 등 제조사 사정으로 가격이 변동될 수 있습니다.
- 신발의 경우, 실외에서 착화하였거나 사용흔적이 있는 경우에는 교환/반품 기간내라도 교환 및 반품이 불가능 합니다.
- 수제화 중 개별 주문제작상품(굽높이,발볼,사이즈 변경)의 경우에는 제작완료, 인수 후에는 교환/반품기간내라도 교환 및 반품이 불가능 합니다.
- 수입,명품 제품의 경우, 제품 및 본 상품의 박스 훼손, 분실 등으로 인한 상품 가치 훼손 시 교환 및 반품이 불가능 하오니, 양해 바랍니다.
- 일부 특가 상품의 경우, 인수 후에는 제품 하자나 오배송의 경우를 제외한 고객님의 단순변심에 의한 교환, 반품이 불가능할 수 있사오니, 각 상품의 상품상세정보를 꼭 참조하십시오.
환불안내
AS안내
- 소비자분쟁해결 기준(공정거래위원회 고시)에 따라 피해를 보상받을 수 있습니다.
- A/S는 판매자에게 문의하시기 바랍니다.
이미지 확대보기
테프가드 PTFE 오픈멤브레인 25X30mm
비밀번호 인증
글 작성시 설정한 비밀번호를 입력해 주세요.
확인장바구니 담기
상품이 장바구니에 담겼습니다.
바로 확인하시겠습니까?
찜 리스트 담기
상품이 찜 리스트에 담겼습니다.